GarmentCuring1 GarmentCuring2

Garment Curing Oven

Bulletin


WRINKLE FREE GARMENT PROCESSING

SAKAV Garment Processing Ovens are designed to heat wrinkle-free clothing on racks with a gentle vertical downflow of air. In the model shown, air is delivered down from the ceiling to return plenums in the floor. Recessed tracks in between the returns allow for the customer cart to be rolled in and out. Processing temperatures to 5000F or as required Heater/blower compartment on the model shown is in the top, keeping bloorscape requirement to minimum.

SPECIFICATION

  • Variable Speed Process Air flow Control (optional) for curing variety of garments and fabrics.
  • 24 hour Temperature Chart Recorder optional.
  • Throughtfully engineered for safety and ease of maintenance
  • Available in Gas or Electrical. Temperature control to maintain close temperature tolerance.
  • Gas Trains.
  • Stainless steel GI interior and exterior walls, ceilings and floor covering for extended operation life
  • Standard and custom design conveyor systems available.
  • Thoughtfully engineered for safety and ease of maintenance.
  • Cycle timer with alarm to prevent over curing or under curing of garments.
  • Safety Stop Switch to prevent operation when doors are open.
  • Lockout / Tagout integrated door disconnect switch

SPECIFICATIONS

Model Elite

I-EH

I-GH

II-EH

II-GH

IV-EH

IV-GH

Length Inches (mm) (w/o conveyor)

48"  (1220)

48" (1220)

108" (2745)

108" (2745)

168" (4270)

168" (4270)

Width (add 12" for control box

64"  (1625)

64" (1625)

64" (1625)

64" (1625)

64" (1625)

64" (1625)

Height

84" (2135)

84" (2135)

84" (2135)

84" (2135)

84" (2135)

84" (2135)

Electrical Service

Standard

230 volts 50 cycle 3 phase (for other voltage contact factory)

Name Plate

40

5

130

12

260

15

Kilo watts

15

2

50

5

100

6

Gas Requirements  
Natural Gas, Propane, or LP Gas, DIESEL For Other Gas supply  Contact  Factory

Gas Line

½”

0.5”

1”

Operation Gas

Pressure (w.c)

10-16”

w.c.

10-16”

w.c.

10-16”

w.c.

Operation Gas

Pressure (Mbar)

24-40

mbar

24-40

mbar

24-40

mbar

Burner rating

BTU

200,000

400,000

800,000

Average usage

BTU

75,000

125,000

250,000

Average usage

Watts

22,700

36,650

73,500

Ventilation Requirements

Exhaust Duct

Size (mm)

12”

(305)

12”

(305)

12”

(305)

12”

(305)

12”

(305)

12”

(305)

Gas Train Vent

(GH Model Only)

 

1”

1”

Send Enquiry